Installation Procedure

    Fig 1: Filler Tube & Seal
    GM744703Courtesy of GENERAL MOTORS CORP.
  1. Install a new seal (2) into the transmission case.
  2. Remove the container used to catch the used transmission fluid from under the vehicle.
  3. Lightly lubricate the filler tube (1) and seal (2) with clean transmission fluid to ease installation.
  4. Install the filler tube (1) into the seal (2).
  5. Lower the vehicle.
  6. Fig 2: Filler Tube
    GM1302099Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Fastener Caution .
  7. Install the nut (3) securing the filler tube (1) to the AIR stud (2).

    Tighten:  Tighten the filler tube nut to 12.5 N.m (111 lb in).

  8. Install the filler tube indicator.
  9. Fill the transmission to the proper level. Refer to Transmission Fluid Level and Condition Check .