Installation Procedure
- Remove any dirt, grease, or other impurities from the mounting surfaces.
- Position the sensor (1) near the radiator support.
- Connect the sensor electrical connector.
- Install the CPA to the sensor electrical connector.
- Install the sensor assembly to the radiator support.
- Install the 2 fasteners (1) retaining the discriminating sensor assembly to the radiator support.
Tighten: Tighten the bolts to 9 N.m (80 lb in).
- Install the engine shield. Refer to Grille Replacement .
- Enable the SIR system. Refer to SIR Disabling and Enabling .
CAUTION:
Refer to Fastener Caution
.