Harmonic Dampers
| Condition | Code | Procedure |
|---|---|---|
| Application incorrect | B | Require replacement |
| Attaching hardware broken | A | Require repair or replacement of hardware |
| Attaching hardware missing | C | Require replacement of hardware |
| Attaching hardware not functioning | A | Require repair or replacement of hardware |
| Cracked | B | Require replacement |
| Dented (fluid type only) | A | Require replacement |
| Keyway distorted | A | Require repair or replacement |
| Leaking (fluid damper only) | A | Require replacement |
| Loose | A | Require replacement |
| Noisy | A | Require replacement |
| Outer ring slipped out of position | A | Require replacement |
| Positioned incorrectly | A | Require repair or replacement |
| Rubber damping material deteriorated | 1 | Suggest replacement |
| Seal surface worn, causing a leak | A | Require repair or replacement |
| Threads damaged | A | Require repair or replacement |
| Threads stripped (threads missing) | A | Require replacement |