Diagnostic Fault Information
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Heated Seat Module B+ | 1 | 1 | - | - |
| Lumbar Adjuster Switch B+ | 1 | 1 | - | - |
| Heated Seat Switch Signal | 1 | 1 | 1 | - |
| Heated Seat Cushion Temperature Sensor Signal | 1 | 1 | 1 | - |
| Heated Seat Heater Element Control | 1 | 1 | 2 | - |
| Heated Seat Cushion Temperature Sensor Low Reference | - | 1 | - | - |
| Heated Seat Heater Element Ground | - | 1 | - | - |
| Heated Seat Module Ground | - | 1 | - | - |
| 1. Heated seat inoperative 2. Heated seat always ON |
||||