P023A-53 Logged After Configuring A New Powertrain Control Module (Pcm) (SSM74148)
Reference number: SSM74148
P023A-53 LOGGED AFTER CONFIGURING A NEW POWERTRAIN CONTROL MODULE (PCM)
TECHNICAL SERVICE BULLETIN
| LAND ROVER: | Discovery/L462; Range Rover/L405; Range Rover Sport/L494 |
| SERVICE CATEGORY: | Diagnostic Software Hardware |
ISSUE
After successfully completing the configuration of a new Powertrain Control Module (PCM), the DTC P023A-53 : "Charge Air Cooler Coolant Pump Control Circuit/Open - Deactivated" is stored and will not erase.
CAUSE
During the configuration process, the routine to activate the Charge Air Cooler Coolant Pump should have been completed, but this job is missing in the Pathfinder application.
ACTION
This workaround will load a software file to the Jaguar Land Rover Approved Diagnostic Equipment using the Manual Patch Update process.
This manual patch will activate the stand alone application Enable/Disable Charge Air Cooler Water Pump in the ECU Functions menu to allow the technician to complete the missing application.
This Manual Patch will stay on the JLR Approved Diagnostic Equipment.
- Restart the JLR Approved Diagnostic Equipment
- Select 'Manual Patch' Icon on the Application Launcher screen. Make sure that both Symptom Driven Diagnostics (SDD) and PATHFINDER are closed before opening the Manual Patch downloader.
- A pop-up will be displayed for Manual Patch downloader
- Enter 'MP_PF_R0022 ' in the Patch Name field.
- Select 'Start'.
- The Manual Patch downloader will then download the manual patch.
- When the patch download has completed, a message will be displayed, asking the user to confirm that the application can run the manual patch. Select 'Yes'.
- When complete, the following message will be displayed: 'Successfully downloaded and started manual patch. Please make sure that the patch has installed successfully.'NOTE: This message will end after 10 seconds.
- Start a new diagnostic session.
- Complete the application Enable/Disable Charge Air Cooler Water Pump .
- Close the session.
- Restart the JLR Approved Diagnostic Equipment.
Technicians - Please rate this SSM and provide comments so that future communications can be improved.
1 = Poor - Basic information provided - The SSM does not help me resolve the customer concern.
3 = Average - Adequate information provided - The SSM partially helps me resolve the customer concern.
5 = Excellent - All required information provided to resolve the customer concern.