Climate Control Blower Motor Intermittent Operation (LTB00875)
Reference number: LTB00875
CLIMATE CONTROL BLOWER MOTOR INTERMITTENT OPERATION
TECHNICAL SERVICE BULLETIN
| LAND ROVER: | 2014-2016 Range Rover (LG); 2014-2016 Range Rover Sport (LW) |
| SECTION: | 412-00 |
| AFFECTED VEHICLES: | Range Rover (LG) Model Year: 2014-2016 VIN: 188776-251188 Manufacturing Plant: Solihull; Range Rover Sport (LW) Model Year: 2014-2016 VIN: 394447-550142 Manufacturing Plant: Solihull; Range Rover Sport (LW) Model Year: 2015-2016 VIN: 600073-633119 Manufacturing Plant: Solihull |
MARKETS
All
CONDITION SUMMARY
Situation: A customer may express a concern that the climate control blower cuts out during operation.
Cause: When the climate control is on maximum or if the blower motor is manually put to maximum, there is potential for the motor to hit the upper limit for current and it will then cut out. This can be reset by either cycling the ignition or by cycling the climate control off and on manually. The fault is intermittent because it is highly dependent on the state of charge of the battery and the inputs to the system, it is rare for the motor to hit the upper limit of current. Suggested Customer Concern Code CF1 .
Action: Should a customer express this concern, follow the Service Instruction below.
TOOLS
JLR approved diagnostic tool
DVD143.04 and Calibration File 220 loaded or later
JLR approved battery support unit
WARRANTY
| DESCRIPTION | SRO | TIME (HOURS) | CONDITION CODE | CAUSAL PART |
|---|---|---|---|---|
| Reconfigure the Automatic Temperature Control Module | 86.90.89.29 | 0.2 | 42 | LR070387 |
DIAGNOSTIC PROCEDURE
-
CAUTION: This procedure requires DVD143.04 and Calibration File 220 loaded or later.
Connect the JLR approved battery support unit.
- Connect to the vehicle and begin a new diagnostic session, by reading the vehicle identification number (VIN) for the current vehicle and initiating the data collect sequence.
- If the hyperlink is not available, the application can be found as follows:
- Select the Diagnosis Session Type.
- Select any of the following symptoms:
- Electrical - Climate control system - Blower operation
- From 'Recommendations', run: Configure existing module - Heating ventilation and air conditioning control module
- Follow all on screen instructions.
- When all tasks are complete, exit the current session by selecting the 'Session' tab and then selecting the 'Close Session' option.
- Disconnect the JLR approved diagnostic tool and the JLR battery support unit.