Manual Tow Bar Cannot Be Configured Using Pathfinder (SSM74821)
Reference number: SSM74821
MANUAL TOW BAR CANNOT BE CONFIGURED USING PATHFINDER
TECHNICAL SERVICE BULLETIN
| LAND ROVER: | Discovery/L462; Discovery Sport/L550; New Range Rover Evoque/L551; Range Rover/L405; Range Rover Evoque/L538; Range Rover Sport/L494; Range Rover Velar/L560 |
| SERVICE CATEGORY: | Diagnostic Software Hardware |
ISSUE
When attempting to complete the application to configure a Manual Tow bar, PATHFINDER reports the error message that follows:
"Domain [3149] not found"
CAUSE
PATHFINDER is incorrectly trying to wake up a module that it may not be fitted in the vehicle.
ACTION
This workaround will load a software file to the Jaguar Land Rover Approved Diagnostic Equipment using the Manual Patch Update process.
This Manual Patch will stay on the JLR Approved Diagnostic Equipment.
To apply the Manual Patch please, complete the instructions carefully.
- Restart the JLR Approved Diagnostic Equipment
- Make sure Symptom Driven Diagnostics (SDD) and PATHFINDER are closed. Then select the 'Manual Patch' Icon on the Application Launcher screen. You will see a pop-up for the Manual Patch downloader.
- Enter 'MP_PF_R0121' in the 'Patch Name' field.
- Select 'Start' and the Manual Patch will download.
- Select 'Yes' when the patch download is finished.
- Start a new PATHFINDER session
- Select 'Service'
- Select 'Add or remove tow bar'
- Complete the application selecting all required options
If this Manual Patch fails to correct the concern, a Technical Assistance (TA) should be submitted using the manual patch number as a reference within the customer concern field, also quoting the communication reference number that the patch was taken from.
NOTE: If this Manual Patch is not being installed on all JLR Approved Diagnostic Equipment you may wish to consider labelling the machine.
PERMANENT CORRECTIVE ACTION
Once the permanent corrective action has been released, this communication and Manual Patch will be expired. An updated bulletin will be released detailing which JLR Approved Diagnostic Equipment version includes the permanent corrective action.