Causes

  • Open or broken signal wire between sensor and ECM
  • Corroded or disconnected sensor connector
  • Failed bypass valve position sensor (potentiometer or Hall sensor)
  • Poor or missing ground or reference voltage to the sensor
  • Water intrusion or physical damage to harness/connector
  • Intermittent connector contact or pin damage

Symptoms

  • Malfunction Indicator Lamp (MIL) illuminated
  • Reduced engine power or limp-home mode
  • Erratic or incorrect boost control (low or uncontrolled boost)
  • Poor throttle response or hesitation under load
  • Possible engine surging or turbo spool irregularities
  • Stored DTC(s) related to boost control or sensors

What to check

  • Retrieve freeze-frame and pending codes with a scan tool; confirm P2C2A is current
  • Check for other stored turbo/boost related codes
  • Visually inspect wiring and connectors at bypass valve B and along the harness for damage, corrosion or water ingress
  • Inspect bypass valve for mechanical binding or physical damage
  • Backprobe sensor connector with ignition on and observe live data for position value or signal voltage
  • Check reference voltage (typically 5 V) and ground at the sensor harness with key on

Signal parameters

  • Sensor type: position sensor (potentiometer or Hall-effect) — signal varies with valve movement
  • Reference voltage: ~5.0 V (key ON, engine OFF) to sensor reference pin (verify with OEM data)
  • Signal voltage (typical, manufacturer dependent): closed/low position ~0.2–1.0 V; open/high position ~3.5–4.8 V — voltage should change smoothly as valve moves
  • If sensor is PWM type: duty cycle should vary smoothly from ~0% to ~100% as the valve moves
  • If potentiometer type: end-to-end resistance commonly in the 1–20 kΩ range (check OEM spec)
  • No signal (open) or stuck at a fixed voltage indicates wiring or sensor fault

Diagnostic algorithm

  1. Confirm the code and capture freeze-frame/live-data with a scan tool; note engine conditions when the code set.
  2. Perform a visual inspection of sensor B, harness and connector for damage, corrosion, oil or water. Repair obvious damage.
  3. With key ON (engine OFF), backprobe the sensor connector: verify reference voltage (~5 V) and a good ground. If no reference or ground, trace and repair circuit cause.
  4. With harness connected, operate the bypass valve (command with bi-directional control if available) while watching the sensor signal voltage/position value. Signal should vary smoothly; if not, suspect sensor or wiring.
  5. If the signal is absent (open), disconnect the harness and measure continuity from sensor signal pin to ECM signal pin. Repair any open circuits.
  6. Check sensor internal resistance (if potentiometer) per OEM spec; infinite/open indicates failed sensor. If Hall-effect, check for signal toggling or proper voltage levels when valve moves.
  7. Perform wiggle test on wiring and connector while monitoring signal to find intermittent opens. Repair or replace damaged wiring/connector as needed.
  8. If wiring and connector are good but sensor remains open/no-signal, replace the bypass valve B position sensor.
  9. After repair, clear codes and perform functional test / road test to verify proper operation and that the code does not return.
  10. If problem persists after sensor and wiring repairs, test/replace ECM or consult manufacturer-level diagnostics for ECM input circuit faults.

Likely causes

  • Disconnected or corroded harness connector at valve B position sensor
  • Broken or chafed signal wire (open) between sensor and ECM
  • Failed internal sensor element (open circuit)
  • Poor ground at sensor or damaged ground circuit
  • Water damaged sensor or connector causing open-circuit

Fault status

⚠️ Status
Stored when the ECM detects an open or no-signal condition on the turbocharger/supercharger bypass valve B position sensor circuit. The ECM cannot determine valve B position, which may affect boost control and trigger MIL.
🟡 Repair difficulty: Medium
⏱️ Diagnostic time: 0.5-1.5 hours

Similar codes

3,330

The library contains 3,330 repair and diagnostic manuals. Choose a brand to open the full manual tree by year, model and trim.

Your experience will help others
+100 karma for a short comment :)
Send to email