Code
P2D29
Generic
P — Powertrain
A/C Compressor Motor Stalled
AI status
Completed
Completed
100%
Causes
- Mechanical seizure of compressor (internal damage, bearing failure, seized shaft)
- Electrical failure in e-compressor motor (shorted windings, internal damage)
- High-resistance or open power supply (fuse, relay, connector, wiring)
- Ground fault or poor ground connection
- Compressor clutch failure or air gap excessive (for belt-driven compressors)
- High refrigerant pressure causing hydraulic lock
Symptoms
- A/C cooling reduced or stops when compressor commanded ON
- Compressor does not spin or clutch does not engage
- High amp draw from A/C circuit or blown circuit protection
- Unusual noises from compressor (grinding, growling) or no noise if seized
- Possible engine stumble or increased load when compressor command applied
- MIL or A/C warning light and stored DTC P2D29
What to check
- Retrieve freeze-frame and full DTC list; note conditions when fault set
- Visual inspection: wiring harness, connectors, fuses, relays, and grounds
- Check refrigerant system pressure (static and when commanded on) with gauges
- Listen for compressor operation and inspect belt condition/tension (if belt-driven)
- Measure battery voltage at compressor connector with A/C commanded ON
- Measure compressor motor current with clamp ammeter during run attempt
Signal parameters
- Compressor command signal (PCM/ACM): ON/OFF status (logic level or CAN command)
- Compressor motor supply voltage: ~battery voltage (12 V or system voltage) when ON
- Motor control PWM duty cycle (if applicable) and motor current (A)
- Compressor RPM or motor speed feedback (if present) — expected >0 when commanded
- Refrigerant high/low pressure readings (psi/bar) — should be within normal range
- Current sensor or fuse-trip threshold reading — compare to factory stall/current spec
Diagnostic algorithm
- Verify and record DTCs and freeze-frame data. Clear codes, then reproduce fault by commanding A/C ON and observing.
- Perform a visual and connector inspection for damage, corrosion, loose pins, blown fuses and failed relays. Repair as needed.
- With A/C commanded ON, measure voltage at compressor power connector; should be near battery voltage. No voltage indicates control or supply fault.
- Measure ground integrity at compressor ground. Clean/repair poor ground connections.
- Measure current draw with clamp ammeter while compressor is commanded ON. Compare to spec. Stall/overcurrent indicates mechanical lock or shorted motor.
- Check refrigerant pressures with gauges static and during operation. Extremely high pressure or locked pressures indicate hydraulic lock or blockage.
- Attempt to rotate compressor shaft by hand with system depressurized and belt removed (if applicable). If shaft cannot turn, compressor is mechanically seized — replace compressor.
- If shaft turns freely and current is within spec but control reports stall, inspect/current-sense circuit, motor controller, and associated fuses/relays. Check for intermittent wiring (backprobe while moving harness).
- If e-compressor motor shows shorted windings or insulation failure (resistance out-of-spec), replace compressor assembly.
- After repairs, evacuate, recharge A/C system to spec (if opened), clear codes, and verify proper operation and no recurrence.
Likely causes
- Internal mechanical seizure or bearing failure in compressor
- Shorted or damaged e-compressor motor windings causing excessive current
- Blown fuse/failed relay or poor connector causing intermittent power
- High refrigerant pressure (overcharge, condenser blockage) preventing rotation
- Faulty current-sense or motor control electronics reporting stall erroneously
Fault status
Status
Stored when compressor motor is commanded ON but motor speed is zero or motor current exceeds the stall threshold. The system detected a stall condition or inability to rotate the compressor while running.
Repair difficulty: Medium
Diagnostic time: 0.5-3.0 hours
Similar codes
Repair manuals
Brands with available manuals
11,062
The library contains 11,062 repair and diagnostic manuals. Choose a brand to open the full manual tree by year, model and trim.
ALFA ROMEO
89
AUDI
1,243
BMW
479
CADILLAC
206
CHEVROLET
917
CHRYSLER
193
DAEWOO
75
FIAT
26
GENESIS
207
HUMMER
138
HYUNDAI
371
ISUZU
229
JEEP
913
KIA
155
LAND ROVER
413
LEXUS
280
LINCOLN
166
MERCEDES-BENZ
856
MERCURY
296
MITSUBISHI
406
PORSCHE
136
TESLA
81
TOYOTA
2,209
TRIUMPH
131
VOLKSWAGEN
626
VOLVO
221
Your experience will help others
+100 karma for a short comment :)
Was this AI description helpful?
Your feedback helps improve AI descriptions.
👍 Like
0
👎 Dislike
0
Send to email