Home / DTC / B1316 — Timeout error (Topstack up)

B1316 — Timeout error (Topstack up)

Detailed page for trouble code B1316.

34,416codes
59brands
11,925generic
22,491specific
Reset
Code

B1316

MITSUBISHI B — Body

Timeout error (Topstack up)

Brand: MITSUBISHI
Type: B — Body
AI status
Completed
ready
Completed 100%
Page language: EN

Causes

  • Mechanical obstruction or binding in roof/stack mechanism
  • Failed or intermittent position/limit switch or sensor
  • Faulty convertible top motor, pump or actuator
  • Low battery voltage or poor power supply to top motor/control unit
  • Damaged wiring harness, corroded connectors or open/short circuits
  • Blown fuse or faulty relay in top power circuit

Symptoms

  • Convertible/top will not complete the 'up' (closed) cycle
  • Top movement stalls or stops before seating
  • Warning lamp or message related to roof operation
  • Audible motor or pump noise without completion
  • Stored B1316 code in vehicle memory
  • Top latches do not engage or alignment is off

What to check

  • Read and record freeze-frame and live data with a capable scan tool
  • Attempt to run the top cycle and observe behavior and timing
  • Visually inspect roof mechanism for obstructions, broken parts, or misalignment
  • Check battery state-of-charge and terminal condition; measure voltage during operation
  • Inspect fuses and relays related to the convertible-top circuit
  • Inspect connectors and wiring for damage, corrosion, or poor contacts

Signal parameters

  • Command input from control switch (on/off state)
  • Motor/pump supply voltage (V) during operation — should be near battery voltage
  • Motor current draw (A) — excessive or zero can indicate stall or open circuit
  • Position/limit sensor feedback (binary or analog) — expected change when top moves
  • Time-to-complete open/close operation (seconds) — compare to factory spec
  • Diagnostic trouble code presence and freeze-frame data (voltage, temp, timestamp)

Diagnostic algorithm

  1. Verify battery voltage and charge; ensure terminals are clean and tight before testing
  2. Connect scan tool, read/record B1316 and any other stored codes, view freeze-frame/live data
  3. Attempt to reproduce the fault while monitoring motor voltage and position sensor signals
  4. Visually inspect roof path and remove any obstructions; manually move linkage (if safe) to check for binding
  5. Check fuses and relays for the top circuit; replace if faulty
  6. Test position/limit switches for proper switching and continuity; clean or replace as needed
  7. Check motor/pump supply and ground for proper voltage while operating; if voltage present but no movement, suspect motor/pump or mechanical jam
  8. Measure motor current during operation to detect overload/stall
  9. Inspect wiring harness and connectors for corrosion, damage, or poor mating; repair as necessary
  10. If hydraulic, inspect lines, actuator and fluid level; repair leaks and top up fluid to spec
  11. Clear codes after repairs and run multiple cycles to confirm proper operation; if B1316 returns, trace/control unit and replace components per service manual guidance

Likely causes

  • Mechanical obstruction or jam in linkages
  • Failed/dirty position or limit switch on roof/trunk
  • Weak battery or poor battery connections causing voltage drop
  • Faulty motor/pump drawing excessive current or stalling
  • Corroded connector or damaged wiring to top motor or sensors

Fault status

⚠️ Status
Timeout occurred during convertible/top 'up' operation — control unit did not detect completion within expected time.
🟡 Repair difficulty: Medium
⏱️ Diagnostic time: 1-3 hours

Similar codes

406

Browse 406 MITSUBISHI manuals: repair procedures, diagnostics, wiring diagrams, component locations, service data and Labor Times by year, model and trim.

MITSUBISHI

Your experience will help others
+100 karma for a short comment :)
Send to email