Code
B1398
FIAT
B — Body
Front left electric window relay circuit
Views:
UK: 5
EN: 6
RU: 6
AI status
Completed
Completed
100%
Causes
- Blown fuse for power windows or relay feed
- Faulty front-left window relay (stuck, coil open/short)
- Poor, corroded or disconnected connector at relay, switch, motor or BCM
- Broken, shorted or high-resistance wiring in the relay feed, control or ground circuits
- Faulty front-left window switch or motor
- Water ingress or corrosion in door harness or connectors
Symptoms
- Front-left window does not move or is intermittent
- No audible click from the relay when the switch is operated
- Relay clicks but window does not move (possible motor or wiring issue)
- Burnt smell or evidence of heat at relay or connector
- Other body electrical anomalies if BCM outputs affected
What to check
- Scan for stored codes and freeze-frame data; note related body or window codes
- Visually inspect fuses, relay, relay socket, connectors and wiring for corrosion, melted insulation or water ingress
- Check fuse continuity and correct fuse rating in the power window circuit
- Swap the front-left window relay with an identical known-good relay (if available) and retest
- Backprobe relay socket while operating switch: verify battery voltage present on feed terminal and control change when switch is actuated
- Measure voltage at the front-left window motor connector while operating switch (should see ~12 V and ground depending on direction)
Signal parameters
- Supply voltage: ~12 V (11–14 V) at relay feed and motor supply when battery is charged
- Relay coil resistance: typically ~50–200 Ω (varies by relay) — coil should not be open or shorted
- Motor current draw: nominally 5–20 A during movement, with higher inrush current at start; sustained high current indicates motor or mechanical binding
- Control signal: relay coil should be energized (12 V) or switched to ground by the driver module when activated — verify change when operating switch
- Intermittent or no change in voltage when switching indicates open/short/intermittent control circuit
Diagnostic algorithm
- Retrieve DTCs and related codes with a scan tool; record freeze-frame and attempt to reproduce the fault.
- Perform a visual inspection of fuses, relay, relay socket, wiring harness (door boot area), connectors and motor for damage or corrosion.
- Verify fuse continuity and presence of battery voltage at the relay feed terminal with ignition on.
- Swap the suspect relay with a known-good identical relay and re-check operation to quickly isolate relay vs. circuit.
- Backprobe relay control and feed terminals while operating the window switch: confirm feed is stable 12 V and control changes (energizes) when commanded.
- Measure voltage at the front-left window motor connector during operation — if no voltage present while relay energizes, trace wiring between relay and motor for opens.
- Check ground continuity from motor and relay ground to chassis. Repair any high-resistance grounds.
- If relay and wiring check OK, bench-test the window motor to confirm motor draws normal current and operates freely. Replace motor if stuck or draws excessive current.
- If wiring, relay and motor good but command signal absent or abnormal, inspect/scan the BCM or door module outputs and connectors; consult wiring diagrams and test module outputs for faults.
- Repair or replace faulty component(s) (fuse, relay, wiring, connector, switch, motor, or module), clear DTCs and retest multiple cycles to confirm repair.
Likely causes
- Loose or corroded connector at the window relay or relay socket
- Failed window relay (coil open or contact welded)
- Blown fuse or poor fuse contact
- Broken/shorted wire between relay and window motor or BCM
- Faulty window switch or motor drawing excessive current
- Intermittent BCM output or damaged module connector
Fault status
Status
Front-left power window relay circuit fault detected — open/short/intermittent in relay feed, control or ground. Inspect relay, fuses, wiring, connectors, switch and motor; verify BCM output if required.
Repair difficulty: Medium
Diagnostic time: 0.5-2.0 hours
Similar codes
Your experience will help others
+100 karma for a short comment :)
Was this AI description helpful?
Your feedback helps improve AI descriptions.
👍 Like
0
👎 Dislike
0
Send to email
