Causes

  • High-voltage DC bus undervoltage/overvoltage
  • Inverter module internal fault (power electronics or control board)
  • Failed inverter cooling (pump/coolant leak/blocked radiator)
  • Intermittent or failed high-voltage contactors or fuses
  • Poor HV or low-voltage grounding/connector corrosion or damage
  • Faulty sensors (current sensors, temperature sensors, voltage sense)

Symptoms

  • Hybrid system warning light or malfunction indicator lamp (MIL) ON
  • Reduced engine or motor power, limp or restricted mode
  • Loss or reduction of regenerative braking
  • Unable to start EV-only operation or charge/discharge functions limited
  • Abnormal inverter or HV battery temperature readings
  • Diagnostic trouble codes stored for inverter, motor generator, or HV battery

What to check

  • Read and record all stored DTCs and freeze-frame data from hybrid/inverter, HV battery and PCM using an OEM-capable scanner
  • Check for active safety interlocks and vehicle in limp mode (note symptoms)
  • Visually inspect inverter and associated HV cabling for damage, corrosion, loose connectors, burned wires or signs of coolant leaks
  • Verify inverter coolant level, pump operation and radiator/hoses for restriction or leaks
  • Confirm auxiliary (12V) battery voltage and grounds are good
  • Check HV fuses, fusible links, and contactors for correct operation and continuity (with HV system de-energized and following safety procedures)

Signal parameters

  • HV battery pack voltage (V)
  • DC-link / inverter DC bus voltage (V)
  • Inverter output phase currents (A) and motor current (A)
  • Motor/generator RPM (rpm)
  • Inverter temperature(s) (°C) and coolant temperature (°C)
  • Contactors state (open/closed) and HV fuse status

Diagnostic algorithm

  1. Safety first: follow manufacturer HV safety procedures and isolate/de-energize HV system before any physical inspection.
  2. Scan: Connect OEM-capable diagnostic tool, read all inverter/hybrid/HV battery/PCM codes and freeze frame data. Save logs.
  3. Reproduce / Observe: With scanner connected, attempt to reproduce fault while monitoring live signals (DC-link V, inverter currents, inverter temps, contactor states, SOC). Note conditions when fault sets.
  4. Visual & mechanical: With HV isolated, inspect inverter housing, connectors, HV cables, ground straps, cooling lines, and look for corrosion, water ingress, burns or coolant leaks.
  5. Power/ground check: Verify 12V supply and grounds to inverter module; poor 12V supply can cause control faults.
  6. Coolant & thermal: Check inverter coolant level, pump operation, flow, and radiator condition. High inverter temperature often causes performance faults.
  7. HV protection devices: Inspect/measure continuity of HV fuses, fusible links and contactors. Confirm contactors operate correctly under commanded conditions (observe with appropriate HV procedures).
  8. Sensor verification: Check voltage and current sensor signals for plausibility. Compare measured DC-link voltage against pack voltage and expected values.
  9. Communication: Verify CAN/communication integrity to hybrid control module; repair wiring/connectors if intermittent.
  10. Module test: If all external systems good, perform inverter self-tests / actuator tests available via scanner. Follow OEM guidance for module reflash or more advanced internal diagnostics.
  11. Repair & verify: Replace or repair failed components (connectors, contactors, coolant parts, inverter or HV battery parts) as indicated. Clear codes, perform full system relearn if required, and road test to confirm fault does not return.
  12. Note: many steps require certified HV training and OEM procedures. Do not open HV components or perform live HV measurements without proper training and PPE.

Likely causes

  • Loose or corroded HV connectors or grounding straps
  • Bad inverter coolant flow or high inverter temperature
  • Blown HV fuse or damaged contactor
  • Internal inverter IGBT or inverter control unit failure
  • Erroneous inverter current or voltage sensor signal
  • Intermittent CAN wiring or module software fault

Fault status