Code
P2446
Generic
P — Powertrain
AIR System Pump Stuck On Bank 2
AI status
Completed
Completed
100%
Causes
- Stuck or welded relay or stuck high-side/low-side driver keeping pump powered
- Control valve or bypass stuck in the open position allowing pump to run
- Short to battery in pump power feed or control wiring
- PCM or pump control module fault (failed driver)
- Failed air pump motor that is mechanically stuck in run condition or has internal short
- Corroded/poor ground or damaged connector causing erratic operation
Symptoms
- MIL (Check Engine) illuminated and P2446 stored
- AIR pump noise running continuously or audible at times it should be off
- Reduced fuel economy and possible unusual exhaust behavior
- Blown fuse related to the AIR pump circuit (if short draws excessive current)
- Possible premature catalyst heating/damage if pump runs at inappropriate times
What to check
- Scan for codes and freeze-frame data; confirm P2446 and any related codes (P0410, P0411, etc.)
- Use a scan tool to monitor and command the AIR pump ON/OFF (verify PCM commands)
- Visually inspect fuses, pump relay, wiring harness, and connectors for damage or corrosion
- Listen for pump operation and note when it runs relative to engine state and scan tool commands
- Measure voltage and ground at the AIR pump connector with pump commanded OFF and ON
- Check continuity/shorts between pump power circuit and battery, and between control circuit and PCM
Signal parameters
- Battery voltage at pump power feed: ~11–14 V when engine is on (may be fused constant or switched)
- Control/driver signal: either switched ground or switched +12V depending on vehicle — should change state when PCM commands OFF/ON
- Pump current draw (typical range): approx 0.5–5 A (varies by vehicle) — unusually high draw indicates mechanical binding or short
- When commanded OFF by PCM: power to pump or driver should be removed (voltage on control circuit should reflect OFF state)
- When commanded ON by PCM at cold start: pump should be energized for the specified time interval and then turn OFF
Diagnostic algorithm
- Retrieve all stored and pending codes and freeze-frame data. Note engine temperature and conditions when the code set.
- Using a bidirectional scan tool, command the AIR pump OFF/ON. Observe whether the pump follows the commands and whether PCM reports successful commands.
- With the ignition ON (engine off), measure voltage at the pump power terminal and at the control terminal while commanding OFF/ON. Identify whether the power feed or control driver is providing power when it should not.
- Inspect and test the AIR pump relay and related fuses. Swap relay with a known-good identical relay if available to check behavior.
- Disconnect the pump connector and command OFF/ON. If the pump still runs when disconnected, suspect relay or hard-wired short to battery. If pump does not run when disconnected, bench-test the pump separately for internal faults or unexpected behavior.
- Check wiring harness for shorts to battery, corrosion, damaged insulation, or poor ground. Repair any damaged wiring and connectors.
- Inspect AIR control valves, check valves, and bypass components on Bank 2 for mechanical sticking or carbon buildup; clean or replace as required.
- If wiring, pump, and valve operation test good, evaluate PCM/pump control module output. Replace PCM only after confirming other faults have been ruled out and following manufacturer procedures.
- After repairs, clear codes and perform a road/cold-start test to confirm the pump is operating only during intended conditions and that P2446 does not return.
Likely causes
- Stuck relay or relay contacts welded closed supplying constant power to pump
- Short in power feed (fused hot) or stuck high-side driver feeding pump continuously
- Faulty pump control solenoid/valve or stuck bypass that forces pump operation
- Open/shorted wiring or poor connector/ground at pump or relay
- Failed PCM output driver (less common)
Fault status
Status
P2446 — AIR System Pump Stuck On (Bank 2): PCM detects the secondary air injection pump or its control circuit is energized when it should be off on bank 2.
Repair difficulty: Medium
Diagnostic time: 0.5-2.5 hours
Similar codes
Repair manuals
Brands with available manuals
9,524
The library contains 9,524 repair and diagnostic manuals. Choose a brand to open the full manual tree by year, model and trim.
Your experience will help others
+100 karma for a short comment :)
Was this AI description helpful?
Your feedback helps improve AI descriptions.
👍 Like
0
👎 Dislike
0
Send to email
