Home / DTC / P2C6C — Drive Motor “A” Phase Y Current

P2C6C — Drive Motor “A” Phase Y Current

Detailed page for trouble code P2C6C.

35,619codes
59brands
11,925generic
23,694specific
Reset
Code

P2C6C

Generic P — Powertrain

Drive Motor “A” Phase Y Current

Brand: Generic
AI status
Completed
ready
Completed 100%
Page language: EN

Causes

  • Open or short circuit in Phase Y motor conductor between inverter and motor
  • Damaged or corroded high-voltage connector or terminal for Phase Y
  • Faulty current sensing circuit inside the inverter / drive controller
  • Internal motor winding damage or short in Phase Y
  • Poor inverter ground or supply voltage irregularity
  • Water intrusion or insulation breakdown in the motor or harness

Symptoms

  • Reduced drive power or motor derate
  • Drive system warning light / EV system lamp illuminated
  • Intermittent or persistent limp-home mode
  • Unusual motor noise or vibration under load
  • Loss of regeneration / traction control warnings

What to check

  • Retrieve all related codes and freeze-frame data with a capable scan tool (record operating conditions)
  • Visually inspect high-voltage phase cables, connectors, and harness around motor and inverter for damage, corrosion, or water ingress
  • Confirm vehicle high-voltage interlock is safe and remove service plugs / isolate battery before any hands-on HV testing
  • Check for other inverter/motor codes that may narrow fault (phase X/Z, DC link faults, ground faults)
  • Verify vehicle voltage and DC bus health at the inverter (no undervoltage/overvoltage events)

Signal parameters

  • Phase Y current amplitude: should be similar to Phase X/Z under comparable load (values vary by vehicle and load)
  • Waveform: 3-phase AC sine or PWM-derived waveform on all three phases; Phase Y should not be flat or missing pulses
  • DC bus voltage: stable within specification during test (refer to manufacturer values)
  • Imbalance: phase-to-phase current imbalance should be minimal under steady load
  • Frequency: motor electrical frequency proportional to motor speed; Phase Y should match other phases

Diagnostic algorithm

  1. Safety first: follow high-voltage safety procedures. Disable HV system, remove service disconnect and verify with proper HV meter before touching wiring.
  2. Use a scan tool: read freeze frame and live data. Note phase currents, DC bus voltage, and related inverter/motor codes.
  3. Visual inspection: examine Phase Y conductor, connectors and motor for damage, heat discoloration or moisture. Repair any obvious damage.
  4. Wiggle test: with vehicle safe and powered down, flex connectors and wiring to check for intermittent faults. Re-check codes after any movement tests.
  5. Measure insulation/resistance: with HV isolated, measure resistance between phase conductors and to ground per manufacturer procedure to detect shorted winding or insulation breakdown.
  6. Power-on current check: using an approved clamp meter or oscilloscope on phase conductors (only if trained and following HV procedure), compare Phase Y current and waveform to the other two phases while running under similar load.
  7. Swap/compare: if possible and safe, compare measurements to a known-good motor or inverter, or swap connectors between phases only if manufacturer allows to isolate motor vs inverter fault.
  8. Inverter diagnostics: if phase wiring and motor check OK, suspect inverter internal current sensor or driver failure. Follow manufacturer inverter test procedures or send inverter for bench testing/repair.
  9. Repair and retest: repair wiring/connectors or replace failed components. Clear codes and perform road test under the same conditions recorded in freeze-frame to confirm repair.
  10. If uncertain, consult manufacturer-specific procedures and consider high-voltage service center or replacement of inverter/motor assemblies.

Likely causes

  • Loose/corroded Phase Y connector at motor or inverter
  • Intermittent open/short in phase conductor caused by chafing or damaged insulation
  • Failed current sensor or measurement electronics in the inverter
  • Motor internal winding fault (shorted turns) affecting Phase Y current
  • Inverter power transistor or phase driver failure on Phase Y output

Fault status

⚠️ Status
Drive Motor A Phase Y current abnormal — inverter detected open/short or out-of-range current on Phase Y. Motor may be derated; inspect phase wiring, connectors, inverter and motor windings.
🔴 Repair difficulty: Hard
⏱️ Diagnostic time: 2.0 - 4.0 hours